System compatibility test IBM M Pro 6219-37U
 |
System specifications
| CPU |
Single socket 478 Pentium 4 |
| Chipset |
Intel 7205 |
| Expansion slots |
5 PCI 1 AGP |
| Storage I/O |
Onboard Ultra DMA 100/66/33 EIDE controller Onboard Adaptec AIC-7901 Ultra320 SCSI controller Onboard Avance AC'97 audio controller Onboard Broadcom NetXtreme Gigabit network controller Onboard IEEE-1394 host controller Onboard Intel USB v2.0 |
| Front side Bus |
533 MHz |
|
Important note This system has been tested with Windows XP Professional only. Although we expect results to be the same with Windows 2000, we cannot guarantee your results. Please note that Windows 98 and Windows Me are not supported with Matrox RT.X. |
Windows XP test results |
Tested configuration
| CPU |
Single Pentium 4 2.8 GHz |
| BIOS |
IBM version M6E117AUS Date: 12/05/2002 |
| Memory |
512 MB DDR RAM |
| Storage |
System drive and CD-ROM drive on primary EIDE channel. A/V drive on secondary EIDE channel. |
| Software |
Matrox X.tools build 4263 and Adobe Premiere 6.5 |
| Installed expansion cards |
| AGP |
Matrox Parhelia |
| PCI
1 |
|
| PCI
2 |
|
| PCI
3 |
Matrox RT.X |
| PCI
4 |
|
| PCI 5 | |
| Additional required software |
| We installed patches and drivers in the following order: |
| 1 |
Microsoft
Windows XP Service Pack 1, Windows XP Updates, and Driver Updates |
| 2 | Intel Chipset Software Installation Utility, version 5.00.1012 Date: 04/14/2003 | | 3 | Onboard Adaptec AIC-7901 Ultra320 SCSI controller, version 1.01 Date: 12/23/2002 (downloaded from the IBM web site) | | 4 | Onboard Broadcom NetXtreme Gigabit network controller, version 6.34 Date: 05/07/2003 (downloaded from the IBM web site) | | 5 | IBM Alert Standard Format Update, version 1.00 (downloaded from the IBM web site) | | 6 | USB drivers were downloaded from the Microsoft web site, version 5.1.2600.0 |
*16 and 32 refer to color depth in bits |
For more information, see
http://www.ibm.com.
The information in this document is subject to change. For the latest updates to this
information, please check this site often. Matrox does not guarantee that the hardware
listed as recommended will perform adequately to meet any particular customer's needs.
This document shows our results at the time of testing. Changes to these systems may
have occurred since completion of our tests. Contact the motherboard and computer
system vendor for particular BIOS versions. Other untested computer systems may provide
adequate performance; however, you may experience configuration difficulties. This
document was last updated June 16, 2003.
List of validated systems |
|