Matrox Maevex™ Series
![]() ![]() |
![]() ![]() |
Any Video, Anytime, Anywhere
The Matrox Maevex video distribution over IP solution consists of the Maevex 5100 Series encoder/decoder pair that extends 1080p60 video and audio over a standard IP network. Matrox PowerStream software is used to remotely discover and manage the Maevex network, allowing administrators to adjust multiple stream parameters. Based on a dedicated H.264 encode/decode platform, Maevex Series enables excellent-quality, cost-effective video extension and playback over standard LAN connectivity at user-defined low bit rates for minimal network bandwidth consumption.
Video and audio over IP
- Operates on standard 10/100/1000Mb Ethernet networks
- Excellent image quality with very low network bandwidth consumption
- Cost-effective extension over standard COTS network equipment
- Unicast, multicast, and multi-unicast operation
- Auto-detection and discovery on network subnet
Integrated, solid-state encoding/decoding hardware architecture
- Supports Full HD video and audio
- Powerful, intelligent performance with dedicated hardware video decoding component
- Open encoding platform also allows for third-party software decode*
- Supports many resolutions and aspect ratios
- Enables administrator fine-tuning of encoding and decoding parameters
- Allows scaling of input resolutions before encoding and scaling of output resolutions after decoding
Network redundancy support
- Hot plug/unplug support for power, video, and audio
- Local real-time audio and video pass-through and confidence preview on Maevex Encoder
- Integrated network switch on Maevex Decoder enables daisy-chaining, network extension, and redundant network topology
- Failure resilience through power, network, and device auto-recovery features
PowerStream software suite
- Powerful software application bundled with the Matrox Maevex Series
- Remotely manage and monitor the entire Maevex network
- Auto-populate Maevex network devices
- Multiple-instance installation supported
- Password-controlled user access
- Access to device IDs, IP addresses, streaming state, bit rate, and other vitals
Optimized design for unbeatable performance
- No driver components required on the host PC
- No moving parts design for high MTBF
- Low power consumption
- Dust-resistant enclosure
- High-density rack mountable
- Small form factor
*Matrox supports VLC as a software decode platform; Other software media players are expected to be compatible but are not supported directly by Matrox at this time.
| Maevex 5150 Encoder |
Video Input:
|
Video Output:
|
| Audio Line-In: 3.5mm analog stereo audio |
| Audio Line-Out (Local Pass-Through): 3.5mm analog stereo audio |
| Network Connector: RJ45 |
| Maevex 5150 Decoder |
| Network Connectors: 2 x RJ45 (fully switched) |
Video Output :
|
| Audio Line-Out: 3.5mm analog stereo audio |
| Video Encoding / Decoding |
| Single-Channel HD: Up to 1920x1080p60 and 1920x1200(57Hz - TBC) and many more wide-screen and standard-definition resolutions |
| Compression Standard: H.264/Mpeg4 Part 10 (AVC) |
| Profiles: Baseline, Main, High |
| Levels: Up to 4.2 |
| Bit Rates: 100Kbps to 25Mbps |
| Rate Control: CBR, VBR, Favor Speed, Favor Quality |
| Audio Encoding/Decoding |
| Compression Standard: MPEG4 AAC-LC |
| Channels: 2 channel (stereo) |
| Sample Frequency: 32, 44.1, and 48kHz |
| Bit Rates: 96, 128, 192, and 256Kbps |
| Networking Interface |
| 10/100/1000base-T Ethernet |
| Streaming Protocols: UDP, RTP/RTSP/RTCP |
| Command & Control Protocols: HTTP/HTTPS |
| IPV4 Support |
| Unicast, Multicast and Multi Unicast |
| DHCP (Default) / Fixed IP Address Support |
| CAT5-or-Better Network Cables |
| Management Software |
Central Command and Control Application
|
| OS Support: Windows 7/Windows 8 (requires Microsoft .NET 4.5) |
| Power Supply |
| 100-240V AC In, 5VDC Out, 15W |
| DIN4 Locking Power Connector |
| Power Cords/Adapters Included: US, EU, GB/HKG, AU/NZL |
| Regulatory |
| CE/FCC/VCCI/ICES/C-Tick/KCC Class B |
| ROHS/WEEE |
| Environmental |
| Operating Temperature: 0 to 55 degrees Celsius (TBC) |
| Non-Operating Temperature: -40 to 70 degrees Celsius |
| Operating Humidity: 20 to 80% (non-condensing) |
| Non-Operating Humidity: 5 to 95% (non-condensing) |
| MTBF |
| Encoder: 135.05 years @ 40 degrees Celsius (excl. power supply) |
| Decoder: 164.81 years @ 40 degrees Celsius (excl. power supply) |
| External Power Supply: 11.45 years @ 25 degrees Celsius, full load |
| Fanless (no moving parts) |
| Mechanical |
| Dimensions Encoder: 21.59cm x 2.59cm x 10.16cm (8.50" x 1.02" x 4.00") |
| Dimensions Decoder: 12.83cm x 2.59cm x 10.9cm (5.05" x 1.02" x 4.29") |
| Weight Encoder: 378g (excl. external power supply and power cords) |
| Weight Decoder: 286g (excl. external power supply and power cords) |
| Rackmounting (optional rackmount tray) |
| Encoder: dual density - 1u |
| Decoder: triple density - 1u (horizontal mount); or 10-unit density in 3u (vertical mount) |
| Packaging Content |
Maevex Encoder unit:
|
Maevex Decoder unit:
|
| Ordering Information |
| Maevex Encoder P/N: MVX-E5150F |
| Maevex Decoder P/N: MVX-D5150F |
| Maevex Encoder/Decoder Bundle P/N: MVX-ED5150F |
| Warranty Information |
| Two-Year Warranty |
The Matrox Maevex Series comes bundled with Matrox PowerStream—a robust software application that enables remote control and management of the entire Maevex network topology. Installed on a network PC, the command & control application supports a variety of features, making Maevex appliances entirely configurable, manageable, and updateable via the network and all from one or more central locations. PowerStream also allows Decoders to be assigned to streams. Maevex administrators can start and stop streams as well as balance image/stream quality and bit rate by managing a variety of encoding and decoding parameters. Easy adjustment of input and output resolutions and aspect ratios provide administrators with additional flexibility and control.
Key features include*:
- Auto-detect and discover Maevex units on subnet (DHCP server required)
- Identify and manage Maevex Encoder/Decoder IP addresses
- Fine-tune encoding and decoding parameters and network bit rate
- Benefit from automated failure resilience and automated recovery features
- Easily assign streams to one or more Decoders
- Scale down source resolution before streaming to network to allow for managed network bandwidth consumption
- Scale and crop source content on individual Decoder outputs, allowing for flexible display
- Set forced resolutions out to all or individual Decoder outputs
- Choose between the Encoder’s Zero-latency direct pass-through or confidence preview settings
- Adjust ProcAmp controls at local Encoder and/or remote Decoder outputs
- Control HDMI and analog audio mute and volume
- Control user access to PowerStream and the Maevex network with password protection
- Create your own names for all Encoder and Decoder units
- Conveniently access device ID, IP address, streaming state, bit rate, and other variables
- Update firmware easily and conveniently over the network
- Take advantage of supported multiple-instance installation and remote management
- Support for Windows 7 or 8

* Information and software subject to change